This article summarizes the 14 most common questions engineers ask when evaluating a switch from EBG/Miba high voltage thick film resistors to the HVC HVR series. It covers selection basics, process alignment, BOM conversion, validation flow, supply chain issues, and technical details. Each answer is based on practical engineering experience and validated customer projects.
1. Selection Basics and Replacement Logic
Q1: What is the relationship between EBG and Miba Resistors? My drawings use both names.
A: EBG was founded in 1977 in Kirchbach, Austria, and became one of the earliest specialist manufacturers focused on high voltage thick film resistors. In 2010, EBG was acquired by Miba AG, and in 2024 the brand was formally unified under the name Miba Resistors. In other words, legacy EBG part numbers and current Miba part numbers refer to the same physical product line. For selection and ordering, the latest Miba PDF datasheet should be treated as the official reference.
Q2: Can HVC really reach the same quality level as EBG? What evidence supports this?
A: HVC publicly states that its high voltage thick film resistor line is built to the same quality level as globally recognized brands such as EBG. From the process point of view, both product families rely on
the same core technology platform:
Core process comparison:
| Dimension | EBG / Miba | HVC HVR | Conclusion |
| Substrate Material | 96% Al2O3 ceramic | 96% Al2O3 ceramic | Equivalent |
| Resistor Paste | RuO2 thick film | RuO2 thick film | Same material system |
| Firing Temperature | Approx. 850C | Approx. 850C | Same process window |
| Inductance Control | Non-inductive | Non-inductive | Same class |
| Working Temperature | -55 ~ +155C | -55 ~ +155C | Equivalent |
| TCR Coverage | +/-10 ~ +/-250 ppm | +/-25 ~ +/-100 ppm (standard) | Mainstream grades covered |
| Voltage Capability | 22 ~ 96 kV | 35 kV (planar) / 60 kV+ (cylindrical) | Mainstream grades covered; higher levels custom |
| Tolerance Range | +/-0.1% ~ +/-10% | +/-0.5% (F) ~ +/-5% (J) | 0.1% available by custom approval |
In addition, the HVC resistor line is supported by engineers with prior EBG background, which helps ensure strong process alignment. Up to now, companies including Planmeca, Haining Jingyi Electronics (associated with iRay SH688301), Spellman, and Hitek Power have completed qualification or volume validation.
Q3: My PCB footprint was designed around EBG packages. Can HVC be used as a pin-to-pin replacement, or do I need a board redesign?
A: In most cases, no PCB redesign is required. For
planar families such as FBX/FEP/FSX, FPX/FLX, and MTX 967, the HVRGFP/HVRGXP size codes correspond directly to the form factors shown in the original PDF, such as 1/2, 2/2, 3, 4, 5/5, 6/5, and 8/5. MTX 967 replacements should be confirmed with the exact PDF configuration code. For
cylindrical families such as SGT, SGP, and OSX, HVR-BSP uses the standard phi7 body and the body length L maps directly to the EBG suffix. As a practical step, HVC recommends sending the original EBG order code to
sales@hv-caps.com for a final PCB compatibility check before first article approval.
Q4: Can TCR be matched after replacement? Some of our divider circuits are highly temperature-sensitive.
A: Yes. The mainstream EBG TCR ranges of +/-25 to +/-100 ppm are fully covered by HVC standard offerings:
- EBG SGT (+/-25 ppm) → HVR-BSP
-F-25- grade for direct alignment
- EBG SSP/OSP (+/-50 ppm) → HVR-BSP
-F-50- grade
- EBG SGP/OGP (+/-80 ppm) → HVR-BSP standard grade or
-F-80-
For ultra-low TCR options used in MTX 967/969, such as +/-10 to +/-15 ppm, HVC can support equivalent performance through the GHP custom line, subject to original part number review and sample confirmation.
2. BOM Conversion and Validation
Q5: My BOM contains dozens of EBG part numbers. What is the fastest way to convert them to HVC part numbers?
A: Two approaches are recommended:
- Manual table lookup: Use the quick reference family table below to identify the corresponding HVC family, then map resistance value, length, voltage rating, and tolerance into the HVC coding structure.
- One-step BOM matching (recommended): Send the complete BOM in Excel format to sales@hv-caps.com. HVC can normally return a full cross-reference proposal within two working days.
EBG to HVC family quick-reference table:
| EBG / Miba Product Family |
Typical Power |
Typical Voltage |
Package / Size |
HVC Replacement |
| FBX / FEP / FSX | 0.5 ~ 5 W | Up to about 29 kV (family-dependent) | Planar A×B, see PDF | HVRGFP (e.g. HVRGFP 6/5) |
| FPX / FLX | 1.5 ~ 7.5 W | Up to about 22 kV (family-dependent) | Planar A×B, see PDF | HVRGXP (e.g. HVRGXP 4) |
| MTX 967 | 1 ~ 10 W | Up to 35 kV | 967.xx.xx config code | HVR-GHP / HVRGXP custom |
| SGT | 1 ~ 6 W | 4 ~ 30 kV | phi8.2 × L mm | HVR-BSP-7×L |
| SGP / OGP | See PDF | See PDF | phi8.2 / phi3.5 | HVR-BSP / HVR-BOP |
| SSP / OSP | See PDF | See PDF | phi8.2 / phi4.2 | HVR-BSP |
| OSX / SSX / SOX | See PDF | See PDF | Independent cylindrical families | HVR-BSP-7×L |
| PHV | See PDF | See PDF | Encapsulated family | HVR-BSP + encapsulation proposal |
| MTX 968 / 969 | See PDF | 9 ~ 96 kV | Divider / cap-end structure | HVR-BSP sample approval |
| MTX 969 W | 500 ~ 1700 W | 5 ~ 10 kV | Water-cooled | Water-cooled engineering proposal |
| MTX 2000 | 10 ~ 50 W | 40 ~ 80 kV | Divider network | Divider-ratio custom approval |
| ESP | Pulse class | 1 kV DC | 62 mm body | ESP-62/14 / ESP-62/20 → engineering inquiry |
For customers who need a faster engineering reference, the following two tables list representative direct replacements that frequently appear in medical imaging, HV power supply, and industrial inspection BOMs.
Representative planar replacement list:
| EBG / Miba Model | Power | Max. Continuous DC Voltage | Package Size | HVC Replacement |
FBX 1/2 | 0.50 W | 3 kV | 12.90 × 3.40 mm | HVRGFP 1/2 |
FBX 6/5 | 1.20 W | 5 kV | 20.00 × 5.08 mm | HVRGFP 6/5 |
FBX 3 | 3.00 W | 9 kV | 38.30 × 6.60 mm | HVRGFP 3 |
FSX 4 | 4.00 W | 15 kV | 51.30 × 7.50 mm | HVRGFP 4 |
FPX 2/2 | 7.50 W | 16.5 kV | 51.00 × 12.90 mm | HVRGXP 2/2 |
MTX 967.15.51 | 4.50 W | 30 kV | 50.8 × 15.0 mm | HVRGHP15.51 |
Representative cylindrical replacement list:
| EBG / Miba Model | Power | Max. Continuous DC Voltage | Body Size | HVC Replacement |
SGT-39 | 1.50 W | 6 kV | phi8.2 × 39.5 mm | HVR-BSP 40 |
SGT-103 | 4.00 W | 20 kV | phi8.2 × 102.9 mm | HVR-BSP 103 |
SGP-52 | 7.50 W | 10 kV | phi8.2 × 52.1 mm | HVR-BSP 52 |
OGP-26 | 1.90 W | 4 kV | phi4.2 × 26.2 mm | HVR-BOP-3.5×26 |
SSX-124 | 15.50 W | 40 kV | phi8.2 × 123.7 mm | HVR-BSP 124 |
PHV-103 | 12.00 W | 32 kV | phi8.2 × 102.9 mm | HVR-BSP 103 + encapsulation option |
If your project includes a mixed BOM of planar, cylindrical, and custom divider structures, HVC can also return a project-specific model-by-model conversion table rather than only a family-level cross reference.
Q6: What validation tests are required after replacement? What is the minimum test set?
A: At minimum, the following three validation items are recommended, and HVC can support sample-based testing:
- DC withstand test: Hold at 1.5x rated voltage for 60 seconds and confirm no breakdown or flashover.
- Temperature cycling: Run -55 to +155 C for 10 cycles and verify resistance drift stays below 0.5%.
- Partial discharge (PD) test: The most critical check; confirm PD remains below 5 pC at 50% to 80% of rated voltage.
If the application involves pulse loading, pulse energy endurance testing should also be added.
Q7: Can HVC provide free samples? What is the delivery lead time?
A: For target part numbers, HVC can typically provide 2 to 5 free samples. Sample lead time is about 2 weeks, while standard production lead time is usually 3 to 4 weeks, significantly shorter than the 16 to 24 weeks often seen from EBG.
3. Supply Chain and Commercial Questions
Q8: Roughly how much cheaper is HVC compared with EBG?
A: In batch purchasing, customers typically reduce BOM cost by about 20% to 40%. The actual savings depend on the exact part number, quantity, coating requirement, and validation level. The best practice is to send the full BOM for a project-based quotation.
Q9: What if my EBG part number does not appear in the cross-reference table?
A: If the part is non-standard or custom, simply send the full original EBG order code together with the datasheet or photos to
sales@hv-caps.com. HVC's engineering team can normally provide a proposed equivalent within two working days. For standard catalog suffixes, HVC still recommends checking the latest Miba PDF body text first.
Q10: After switching to HVC, can we still keep EBG in place? How should a dual-source strategy be implemented?
A: This is exactly the value of dual-source planning. Once HVC has passed validation and entered your AVL, you can flexibly allocate purchasing volumes based on supply conditions, for example EBG 70% and HVC 30%, or temporarily shifting HVC to 100% when EBG lead time becomes too long. In this sense, dual-source does not mean "replacement only"; it means "operational insurance".
EBG vs HVC supply chain snapshot:
| Dimension | EBG / Miba | HVC |
| Standard lead time | 16 ~ 24 weeks | 3 ~ 4 weeks |
| Sample lead time | 4 ~ 6 weeks | 2 weeks |
| Price level | European manufacturing premium | Typically 20% to 40% lower |
| MOQ | Usually less flexible | Flexible negotiation |
| Capacity flexibility | Long scheduling and difficult rush orders | Fast response and emergency support |
| Technical support | Slower response for Asia-Pacific | Direct China-based engineering support |
| Quality system | IATF 16949 / ISO 9001 | ISO 9001 + internal benchmark control |
| Manufacturing base | Austria / USA | Shenzhen, China |
4. Technical Details
Q11: Does HVC offer products above 60 kV?
A: Yes. By increasing body length in the BSP cylindrical line, such as 76 mm, 103 mm, 127 mm, or 152 mm, HVC can support applications above 60 kV. For extreme cases such as EBG MTX 969 at 96 kV, HVC normally performs a dedicated engineering review including body length and special encapsulation structure. The original part number should always be provided for quotation.
Q12: How should I select the +/-25 ppm low-TCR option corresponding to EBG SGT? How is it coded by HVC?
A: In the HVC BSP series, the -F-25- coding position corresponds directly to the +/-25 ppm TCR grade. For example, HVR-BSP-7x52-100M-F-25-10k indicates a phi7 body, 52 mm length, 100 MOhm resistance, F-grade tolerance (+/-0.5%), +/-25 ppm TCR, and 10 kV rated voltage. Simply specify the TCR target when requesting a quote.
Q13: How do the planar size codes such as 6/5 or 8/5 map between EBG and HVC?
A: In the EBG FBX family, suffixes such as 6/5, 10, and 16 are mechanical form-factor codes. HVRGFP and HVRGXP include equivalent dimensional classes. For example, FBX-6/5 10M 1% can be mapped directly to HVRGFP 6/5 10M 1%, allowing the existing PCB pad layout to be reused.
Q14: Can HVC resistors be used in military or aerospace projects?
A: HVC case references mention validated use by military-grade end users, indicating that the product line has already entered high-reliability programs. If your project requires a specific military screening level, such as a MIL-PRF-based flow, the best approach is to discuss the exact requirement with the HVC engineering team and define a custom qualification path.
If you still have questions during EBG replacement selection, or need one-to-one technical guidance for a specific application, the HVC engineering team is ready to support you. HVC can provide free samples and engineering-level technical assistance for qualified replacement projects.
Copyright Notice: This document is the property of HVC Capacitor. Reproduction or commercial use without permission is prohibited.
Disclaimer: The FAQ content in this article is provided for reference only and is based on HVC product information and engineering practice. Final selection should always be confirmed against the latest official datasheet and project-specific approval requirements. EBG and Miba are registered trademarks of Miba AG. This document is provided solely for technical cross-reference and replacement discussion.